Gas Monitoring

FL4000H MSIR Flame Detector

FL4000H Multi Spectrum IF Flame Detector

FL4000H MSIR Flame Detector

  • Multi-Spectral Infrared (MSIR) sensor array increases the detection range and field of view.
  • Neural Network Technology (NNT) provides superior false alarm immunity.
  • Designed to detect typical fires such as alcohol, n-heptane, gasoline, jet fuels and hydrocarbons.
  • Can also see through dense smoke produced by diesels, rubber, plastics and lube oil fires.
  • 4-20 mA analog output for remote alarm and fault indication.
  • Dual Modbus compatibility with two-way addressable communications for status and alarm information and with optional 8 amp relays (3x).
  • Optional HART digital communication signal transmitted on the 4-20 mA analog signal.

FL3100H UV/ IR Unitized Flame Detector

FL3100H UV IR Flame Detector

FL3100H UV/ IR Unitized Flame Detector

  • FL3100H UV/IR detector is appropriate for either indoor or outdoor use.
  • FL3100H-H2 specifically detects hydrogen fires, with shorter wavelength of 2.7-3.2 micrometers.
  • Three alarm/ fault relays and RS-485 output with Modbus RTU protocol for linking up to 128 detectors, 247 units with repeaters.
  • Designed to detect unwanted fires and provide alarm outputs directly from detector while maintaining false alarm immunity.
  • Explosion-proof housing allows detector information to be processed at the point of detection.
  • Provides a stepped output 4-20 mA signal which indicates the detector’s status.
  • Optional HART digital communication signal transmitted on the 4-20 mA analog signal.

IR5500 Open Path Hydrocarbon Gas Monitoring System

IR5500 Open Path Hydrocarbon

IR5500 Open Path Hydrocarbon Gas Monitoring System

  • Single Detection Beam technology eliminates drift and false alarms.
  • Digital display provides continuous readout of gas concentration and fault codes.
  • Continuous optical check for beam blockage and automatic gain signal reduction.
  • Microprocessor-based IR open path gas monitoring system detects combustible gases and vapors in both LEL•m and ppm•m ranges

Single Point and Multipoint Gas Monitors

IR400S Single Point gas monitor

IR4000S Single Point IR4000S Single Point
IR4000M Multi-Point Gas Monitors
R4000M Multi-Point Gas Monitors

  • Three-digit LED displays gas concentrations in % LEL, fault codes for troubleshooting and calibration prompts.
  • Explosion-proof enclosure allows installation in hazardous locations.
  • Optional 8 Amp relays expands system functions.
  • Magnetic interface provides ease of maintenance and accessibility.
  • IR4000M can connect up to eight remote IR400 or IR5500 gas detector

IR400 Infrared Point Detector IR400 Infrared Point Detector

IR400 Infrared Point Detector

IR400 Infrared Point Detector IR400 Infrared Point Detector

  • Fail-to-safe operation.
  • Reduces maintenance, no routine calibration.
  • 4-20 mA output for remote alarm and fault indication.
  • Modbus compatibility with two-way addressable communication for status and alarm information.
  • Microprocessor-based IR detector that detects combustible gases and vapors within LEL limits.
  • Optional HART digital communication signal transmitted on the 4-20 mA analog signa

S4000CH / S4100C Inteligent Sensors

Consubtible gas monitoring s4000

S4000CH / S4100C Inteligent Sensors

  • Microprocessor-based transmitter designed for use with our reliable catalytic-bead sensors.
  • Remote mounting of sensor increases installation flexibility.
  • 3 digit LED display shows gas concentrations in % LEL, fault codes for troubleshooting and calibration prompts.
  • 4-20mA output for remote alarm and fault indication.
  • Optional HART (S4000CH only) and Modbus communication provides complete status and control capability in the control.

FL3101H UV Unitized Flame Detector

FL310H UV Flame Detector

FL3101H UV Unitized Flame Detector

  • FL3101H UV-only detector detects in UV spectral range, optimized for speed of response.
  • Three alarm/fault relays and RS-485 output with Modbus RTU protocol for linking up to 128 detectors, 247 units with repeaters.
  • Designed to detect unwanted fires and provide alarm outputs directly from detector while maintaining false alarm immunity.
  • Explosion-proof housing allows detector information to be processed at the point of detection.
  • Provides a stepped output 4-20 mA signal which indicates the detector’s status.
  • Optional HART digital communication signal transmitted on the 4-20 mA analog signal.

FL3110 (UV/IR) /FL3111 (UV) Flame Detectors

FL3110 UV IR Flame Detector

FL3110 (UV/IR) /FL3111 (UV) Flame Detectors

  • FL3110 UV/IR detector is appropriate for either indoor or outdoor use.
  • FL3111 UV-only detector detects in UV spectral range, optimized for speed of response.
  • FL3111HT ultraviolet (UV) flame detector operates in high temperatures up to 125°C.
  • Three alarm/fault relays or RS-485 output with Modbus RTU protocol for linking up to 128 detectors, 247 units with repeaters.
  • Explosion-proof housing allows detector information to be processed at the point of detection.
  • Provides a stepped output 4-20 mA signal which indicates the detector’s status.
  • Terminal enclosure certified EExe.

FL3112 Digital Frequency Infrared Flame Detector

FL3112 IR Flame Detector

FL3112 Digital Frequency Infrared Flame Detector

  • Detects radiation from the infrared spectral region of a flame.
  • Three alarm/fault relays or RS-485 output with Modbus RTU protocol for linking up to 128 detectors, 247 units with repeaters.
  • Designed to detect unwanted fires and provide alarm outputs directly from detector while maintaining false alarm immunity.
  • Explosion-proof housing allows detector information to be processed at the point of detection.
  • Provides a stepped output 4-20 mA signal which indicates the detector’s status.
  • Terminal enclosure certified EExe.

TA402A Single-Channel Trip Amplifier

TA402A Single Chennel Trip Amplifier

TA402A Single-Channel Trip Amplifier

  • Zero Two Series panel card with relays for use with our Flame Detectors.
  • Microprocessor-based electronics allow all options to be user selectable through front panel interface.
  • LED indications of status, open collector and relay outputs for fault, low alarm and high alarm.
  • Remote setup and interrogation, via RS-485 serial communications interface, available with CC02A
  • Modbus communications module.

Copyright © 2015 - 2019. All rights reserved.